Automated Demand Response

by | Jul 15, 2018 |

Open DR

 

VT-IPM2M 113/213 Series ADR

Use for all DR Applications when more than 1 Relay Outputs are needed for Pending & Event (Moderate/High) Signals. Interface with Building Automation and Energy Management Systems using Modbus or BACnet. 

Optional 4-20mA outputs on the VT-IPM2M 213 ADR for configurable analog read out or direct control of energy consuming devices. 

  • Industrial platform -40C to 70C Operating Temp.
  • 12 DI, 8 AI & 4 DO
  • 4 High Speed counters for KYZ inputs
  • 2 Analog 4-20mA output (optional with model 213)
  • Modbus RTU/TCP
  • BACnet & DNP3 (optional)
  • Open ADR 2.0a & 2.0b certified
  • GRIDview enabled

more …

VT-MIPM 135 Series ADR

Use for Simple & Special Signal DR Applications or when additional configurable Relay Outputs are needed. Interface with Building Automation and Energy Management Systems using Modbus or BACnet. 

Special Control logic can be provided for Fast Frequency Response or Current Limiting. Custom programming is available. 

  • Industrial platform -40C to 70C Operating Temp.
  • 12 DI, 6 AI & 8 DO
  • 4 High Speed counters for KYZ inputs
  • Modbus RTU/TCP
  • BACnet & DNP3 (optional)
  • Open ADR 2.0a & 2.0b certified
  • GRIDview enabled

more …

ST-IPM 6350 Series ADR

Use as a Master Controller when special programming and communication is required to multiple devices using serial or Ethernet.

  • Industrial platform -40C to 70C Operating Temp.
  • 5 Ethernet Ports – 2 Networks with individual MAC addresses
  • 3 Serial Ports
  • Modbus RTU/TCP & DNP3 Slave
  • BACnet  (optional)
  • Open ADR 2.0a & 2.0b certified
  • GRIDview enabled

more …

GL T24 Series ADR

Use for all new construction required DR enablement such as California Title 24. GL T24 is fully enabled for Open ADR signals and can be fully demonstrated without having an account with the Utility.

  • Industrial platform -40C to 70C Operating Temp.
  • Operates on any local network with access to the Internet
  • Optional 3G or LTE cellular option if no LAN is available and a remote signal is required
  • 1 Ethernet Port
  • 1 RS232 Serial Port
  • Modbus RTU/TCP & DNP3 Slave
  • BACnet  (optional)
  • Open ADR 2.0a & 2.0b certified
  • GRIDview enabled

more …

GL 6021 Series ADR

Use for all Simple DR Applications when 1 Relay Output will suffice  and the ability to communicate to multiple Ethernet devices on a sub-network.  Interface with Building Automation and Energy Management Systems using Modbus TCP or BACnet. 

  • Industrial platform -40C to 70C Operating Temp.
  • Optional 3G or LTE cellular option – configurable for cell fail-over on LAN failure
  • 5 Ethernet Ports – Router can create its own sub-network
  • 1 RS232 Serial Port
  • Modbus RTU/TCP & DNP3 Slave
  • BACnet  (optional)
  • Open ADR 2.0a & 2.0b certified
  • GRIDview enabled
Model Onboard I/O Ports Communication Protocols Network Cloud Connectivity Control Programming
AI AO DI DO RS485 RS232 Ethernet Modbus TCP/RTU BACnet Ethernet DNP3 Ethernet Slave Cellular Router Split LAN GRIDview Historian AWS – MQTT Open ADR VTN IEC 61131 Python, Perl C, C++
VT-IPM2M-113 8 0 12 4 1 1 1 X X X X X X X X X X
VT-IPM2M-213 8 2 12 4 1 1 1 X X X X X X X X X X
VT-MIPM-135 8 0 8 8 2 1 1 X X X X X X X X X X
ST-IPM-6350 1 1 1 2 5 X X X X X X X X X X X
GL-6001 1 1 1 1 X X X X X X X X X X
GL-6021 1 1 1 5 X X X X X X X X X X